Lumenis Coherent VersaPulse PowerSuite 20W Holmium Laser - Fully refurbished
Product name:Lumenis Coherent VersaPulse PowerSuite 20W Holmium Laser - Fully refurbished
#LMN PS 012 0197
Manufacturer:Lumenis
Lumenis Coherent VersaPulse PowerSuite 20W Holmium Laser - Fully refurbished

More info:

VersaPulse PowerSuite 20W Holmium Laser
 Condition: Fully refurbished
Warranty: 6 months

Go to pictures
 Specifications:
 Treatment beam
Wavelength: Holmium (2.1 μm)
Power: 20 watts maximum
Energy: 0.5–2.5 joules per pulse, adjustable in variable increments
Pulse rate: 5–20 pulses/second, adjustable in variable increments
Pulse duration: 600 μs maximum
US FDA CDRH laser classification: Class IV
European EN 60825 laser classification:       Class 4
 Aiming beam
Type: Diode
Power: 5 mW maximum, continuous wave
US FDA CDRH laser classification: Class IIIa
European EN 60825 laser classification: Class 3A
Principal output:                                            Red, 650 nm (± 10 nm)
 Input power
Frequency: 50/60 Hz
Voltage: 110/200/230 VAC ± 10%
Phase: Single
Current: 15A, 120± 10% VAC
10A, 200± 10% VAC
                                                                      10A, 230± 10% VAC
 Cooling:                               Internal water-to-air heat exchanger
 Cooling air requirements:   Minimum 50 cm (20 inches) from walls
 Physical characteristics
Width: 48 cm (19 inches)
Length: 61 cm (24 inches)
Height: 114 cm (45 inches)
Weight:      84 kg (185 pounds)
 Power cable length:          4.6 m (15 feet)
 Footswitch cable length:   5.2 m (17 feet)
 Environmental requirements (operating)
Maximum altitude: 3,050 m (10,000 feet)
Temperature range: 10° C to 30° C (50° F to 86° F) — must be above dew point
Maximum humidity:     90% at 27° C (81° F) non-condensing
 Environmental requirements (nonoperating)
Temperature range: 0° C to 50° C (32° F to 122° F) — must be above dew point
Maximum humidity:     90% at 55° C (131° F) non-condensing

Note: below; a summary of indication for use with the VersaPulse PowerSuite 20W Holmium Laser
Operator Manual to use the machine for these indications you need to read the chapter
"Indication for use" in VersaPulse PowerSuite 20W Holmium Surgical Laser 0640-041-XX
including General warnings, Coutions and the relevant contraindications and the appropriate
CLINICAL PARAMETERS for your indications.
         (This list of indications is a summary and does not replace the manufactirer's instruction)


 Indications for Use Specific to the Ho:YAG WavelengthThe Ho:YAG (2.1 μm) wavelength is intended for use in surgical procedures
involving open, laparoscopic and endoscopic ablation, vaporization, excision,
incision, and coagulation of soft tissue in medical specialties including:
 1. Arthroscopy
  •  Meniscectomy
  •  Plica removal
  •  Ligament and tendon release
  •  Contouring and sculpting of articular surfaces
  •  Debridement of inflamed synovial tissue (synovectomy)
  •  Loose body debridement
  •  Chondromalacia and tears
  •  Lateral retinecular release
  •  Capsulectomy in the knee
  •  Chondroplasty in the knee
  •  Chondromalacia ablation
2. Urology
  • Superficial and invasive bladder, urethral, and ureteral tumors
  • Condylomata
  • Lesions of external genitalia
  • Urethral and penile hemangiomas
  • Urethral strictures
  • Bladder neck obstructions
     
3. Urinary lithotripsy
  • Endoscopic fragmentation of urinary (urethral, ureteral, bladder and renal)calculi, including cystine, calcium oxalate, monohydrate and calcium xalate dihydrate stones
  • Treatment of distal impacted fragments of steinstrasse when guide wires cannot be passed
4. E.N.T surgery
  • Partial turbinectomy
  • Ethmoidectomy
  • Polypectomy
  • Maxillary antrostomy
  • Frontal sinusotomy
  • Sphenoidotomy
  • Dacryocystorhinostomy (DCR)
  • Functional endoscopic sinus surgery (FESS)
5. Gynecological surgery
  • Inability to receive laparoscopic treatment
  • Intolerance to anesthesia
  • Septic peritonitis
  • Intestinal obstruction
  • Septic shock
  • Resection or excision of large, highly vascularized organs
6. General surgery
  • Cholecystectomy
  • Lysis of adhesions
  • Appendectomy
  • Pylorostenotomy
  • Removal of rectal polyps of the sigmoid colon
  • Skin incision
  • Tissue dissection
  • Excision of external tumors and lesions
  • Complete or partial resection of internal; organs, tumors and lesions
  • Mastectomy
  • Hepatectomy
  • Pancreatectomy
  • Splenectomy
  • Thyroidectomy
  • Parathyroidectomy
  • Herniorrhaphy
  • Tonsillectomy
  • Lymphadenectomy
  • Partial nephrectomy
  • Pilonidal cystectomy
  • Resection of lipoma
  • Debridement of decubitus ulcer
  • Hemorrhoids
  • Debridement of statis ulcer
  • Biopsy
7. Gastroenterological surgery
  • Gall bladder calculi
  • Biliary/bile duct calculi
  • Benign and malignant neoplasm
  • Polyps
  • Colitis
  • Ulcers
  • Angiodysplasia
  • Hemorrhoids
  • Varices
  • Esophagitis
  • Esophageal ulcer
  • Mallory-Weiss tear
  • Gastric ulcer
  • Duodenal ulcer
  • Non-bleeding ulcer
  • Gastric erosions
  • Colorectal cancer
  • Gastritis
  • Bleeding tumors
  • Pancreatitis
  • Vascular malformations
  • Telangiectasias
  • Telangiectasias of the Osler-Weber-Renu disease
Pictures:
Lumenis Versapulse Powersuite 20W 2Lumenis Versapulse Powersuite 20W 1Lumenis Versapulse Powersuite 20W 3Lumenis Versapulse Powersuite 20W 4


I BUILT MY SITE FOR FREE USING